Eurocode 3: Design of steel structures

European standard for the design of steel structures, including buildings, bridges, and industrial structures.

Eurocode 3 provides rules for the design of steel structures. It covers material properties, structural analysis, design of members (beams, columns, connections), stability, and fire resistance.

Key Formulas

Steel yield strength

f_yd = f_y / γ_M0

Buckling resistance

N_b,Rd = χ × A × f_y / γ_M1

Bending moment resistance

M_c,Rd = W_pl × f_y / γ_M0

Reference Tables

Partial safety factors for steel

Design situationγ_M0γ_M1γ_M2
Persistent and transient1.01.01.25
Accidental1.01.01.1

Frequently Asked Questions

What is this standard used for?

This standard provides guidelines and requirements for specific calculations and design procedures in its field of application.

How do I apply this standard?

This page provides educational context about the standard. For actual design work, consult the official standard documents and qualified engineers. Our calculators can help with preliminary estimations, but they are not a substitute for professional design.